Legrand Daker Conventional UPS - Single Phase Online Double Conversion VFI UPS, Rack/Tower Mountable

  • Single-phase conventional UPS system
  • 2KVA Power Output
  • VFI-111 online double conversion
  • User-friendly reversible display
  • Matching battery compartment to increase uptime
  • Smart battery management
  • Optional automatic & manual bypass
  • Easily  replacable battery
  • View of the status, system parameters,  battery level & faults
  • Built-in communication software for control & remote diagnostics
  • Communication through SNMP/internet/network adaptor
  • Optional slot for network configuration
  • WEB/SNMP boards & relay interface
  • Automatic & manual bypass (optional)
  • Maintenance bypass switch (MTBS)
₦246,000.00
No tax
Out-of-Stock

Need Help? Reach us:

Call: +234 708 944 4555
        +234 704 455 8888

Livechat: Chat on WhatsApp

Email: sales@swiftermall.com

.................................

- Genuine Quality Always
- Manufacturer's Warranty
- Secured Shopping
- Competitive Pricing
- Delivery Nationwide, on time & to Spec

Product Information: Daker DK Conventional UPS - 2KVA Single phase Online double conversion VFI UPS, Rack/Tower Mountable.

When you're looking for a superior, top performance online UPS, turn to the Legrand Daker DK online UPS series. The Legrand Daker online double conversion technology UPS comes in various capacities to meet your varying needs, ranging from 1kva to 10kva.

With the Legrand Daker 2000 UPS, rated at 2000VA (2KVA), 1600W, you have reasonable power backup to support multiple applliances. while rated for 10 minutes at 70% load, the Legrand daker series offers backup time scalability. You can optionally add more battery cabinets (loaded) to scale up backup time. While the standard 2kva Daker UPS comes with internal battery set of 6 x 12V/7.2Ah batteries for the estimated 10 minute backup at 70% load, the external optional cabinet is fitted with 12 x 12V/7.2Ah battery set. What's more, you can add multiples of the external battery cabinet to keep increasing backup time.

Estimated Backup Time for Daker 2000VA (2KVA) UPS with External Battery Cabinets

Here's what backup time you can hope to get:

  • Standard Daker 2KVA Online UPS , NO External Battery Cabinet: 10 Minutes @ 70% load:
  • Standard Daker 2KVA Online UPS + 1 x External Battery Cabinet (Fitted): 39 Minutes @ 70% load:
  • Standard Daker 2KVA Online UPS + 2 x External Battery Cabinet (Fitted): 1 Hr, 22 min @ 70% load
  • Standard Daker 2KVA Online UPS + 3 x External Battery Cabinet (Fitted): 1 Hr 57 min @ 70% load
  • Standard Daker 2KVA Online UPS + 4 x External Battery Cabinet (Fitted): 2 Hr 44 min @ 70% load

The Legrand Daker DK 2000VA is excellent for business use and is designed for both tower and rack mounting flexibility. Even the LCD display of the Daker UPS series is reversible - it rotates to fit a tower- or rack-mount configuration. This feature-rich, advanced technology Legrand UPS is the right choice, if you can afford it.

More features of Legrand Daker UPS series


Check these advanced features of the Legrand Daker UPS:

  • On‑Line double conversion UPS that can be used in both tower and rack configurations.
  • The main parameters of the system and the status of the UPS, including the battery charge level and faults, are displayed on the LCD screen.
  • Additional battery cabinets are available to increase the backup time of the UPS. A charger can be added in all battery cabinets for fast, safe charging.
  • Reversible screen. With the reversible screen, the Daker DK UPS can be used in both tower and rack configuration.
  • The main parameters of the UPS, including the battery charge level and faults, are displayed on the LCD screen on the front panel.
  • The integrated communication software not only controls the UPS and its switch-off if there is a malfunction, and enables the user to test the main functions remotely, communicate via SNMP/Internet/network adaptor and access the functions of the UPS via the Internet, but can also send the user an SMS if specific events occur.
  • The internal extension connector enables a WEB/SNMP card or a relay interface to be installed which provides insulated contacts for applications on industrial control
  • panels or remote alarm panels.
  • If there is an electronic fault, overload, overheating or for scheduled maintenance operations, the automatic or manual (optional) bypass ensures continuity of the power supply for critical loads. A bypass switch is available for maintenance.

Legrand Daker UPS 2000VA 2KVA Tech Data

New

16 other products in the same category:

Reviews

Write your review

Legrand Daker Dk 2000 Conventional UPS - Single phase 2KVA On-line Double Conversion VFI UPS, Rack/Tower Mountable

Legrand Daker Conventional UPS - Single Phase Online Double Conversion VFI UPS, Rack/Tower Mountable

  • Single-phase conventional UPS system
  • 2KVA Power Output
  • VFI-111 online double conversion
  • User-friendly reversible display
  • Matching battery compartment to increase uptime
  • Smart battery management
  • Optional automatic & manual bypass
  • Easily  replacable battery
  • View of the status, system parameters,  battery level & faults
  • Built-in communication software for control & remote diagnostics
  • Communication through SNMP/internet/network adaptor
  • Optional slot for network configuration
  • WEB/SNMP boards & relay interface
  • Automatic & manual bypass (optional)
  • Maintenance bypass switch (MTBS)

Write your review